Lochinvar Heat Pump 80-Gallon (HPV080KD 2)
Lochinvar Heat Pump 80-Gallon (HPV080KD 2) is a heat pump (hybrid electric) water heater from Lochinvar with a 82 gallon rated tank and a 93 gallon first-hour rating at a 3 UEF.
| Uniform Energy Factor (UEF) | 3 |
|---|---|
| Annual electricity use | 1654 kWh/yr |
| Recovery efficiency | 373 % |
| Fuel | Electric |
|---|
| First-hour rating | 93 gal |
|---|---|
| Rated storage volume | 82 gal |
| Draw pattern | High |
| Heat pump type | 120 Volt Integrated HPWH |
|---|---|
| Refrigerant (GWP) | R-513A (GWP:630) |
| Compressor low-temp cutoff | 37 °F |
| Input voltage | 120 |
|---|---|
| Max current draw | 15 A |
| Smart / connected capable | Yes |
|---|
| Height | 92 in |
|---|---|
| Diameter | 27 in |
| ENERGY STAR certified | Yes |
|---|
Who is the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) for?
- Its 93 gallon first-hour rating suits a household of 5+ people under DOE sizing guidance.
- Estimated running cost: about $281/year at the national average electricity rate (1654 kWh/yr certified use).
- Runs on a 120 V circuit (up to 15 A) — often no new wiring needed.
- The heat pump compressor operates down to 37 °F ambient — below that, backup elements take over.
Similar water heaters
- A. O. Smith Heat Pump 80-Gallon (HPTV-80 2) (UEF 3)
- A. O. Smith Heat Pump 80-Gallon (HPV10-80H01DV 2) (UEF 3)
- American Heat Pump 80-Gallon (HPV10280H009DV 2) (UEF 3)
- RELIANCE WATER HEATERS Heat Pump 80-Gallon (10-80-DHPTV 2) (UEF 3)
- State Heat Pump 80-Gallon (HPVX-80-DHPT 2) (UEF 3)
- GE Profile Heat Pump 80-Gallon (PF80S10FPY01) (UEF 3.5)
Frequently asked questions
Is the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) ENERGY STAR certified?
Yes, the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) holds a current ENERGY STAR certification for water heating efficiency (UEF 3).
How much does the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) cost to run per year?
About $281 per year at national average energy rates, based on its certified annual energy use under the DOE test draw pattern. Your rate and usage change this figure.
What electrical circuit does the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) need?
The Lochinvar Heat Pump 80-Gallon (HPV080KD 2) runs on a 120 V circuit drawing up to 15 A — many installations use an existing outlet with no new wiring.
Is the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) a smart water heater?
Yes, the Lochinvar Heat Pump 80-Gallon (HPV080KD 2) is connected-capable, with app control and eligibility for most utility demand-response programs.
Sources
- data.energystar.gov (retrieved 2026-07-17)