American Heat Pump 50-Gallon (HPV10250H009DV 2) is a heat pump (hybrid electric) water heater from American with a 46 gallon rated tank and a 52 gallon first-hour rating at a 3 UEF.
| Uniform Energy Factor (UEF) | 3 |
|---|---|
| Annual electricity use | 1550 kWh/yr |
| Recovery efficiency | 457 % |
| Fuel | Electric |
|---|
| First-hour rating | 52 gal |
|---|---|
| Rated storage volume | 46 gal |
| Draw pattern | Medium |
| Heat pump type | 120 Volt Integrated HPWH |
|---|---|
| Refrigerant (GWP) | R-513A (GWP:630) |
| Compressor low-temp cutoff | 37 °F |
| Input voltage | 120 |
|---|---|
| Max current draw | 15 A |
| Smart / connected capable | Yes |
|---|
| Height | 63 in |
|---|---|
| Diameter | 15 in |
| ENERGY STAR certified | Yes |
|---|
Who is the American Heat Pump 50-Gallon (HPV10250H009DV 2) for?
- Its 52 gallon first-hour rating suits a household of 2–3 people under DOE sizing guidance.
- Estimated running cost: about $264/year at the national average electricity rate (1550 kWh/yr certified use).
- Runs on a 120 V circuit (up to 15 A) — often no new wiring needed.
- The heat pump compressor operates down to 37 °F ambient — below that, backup elements take over.
Similar water heaters
- A. O. Smith Heat Pump 50-Gallon (HPTV-50 2) (UEF 3)
- A. O. Smith Heat Pump 50-Gallon (HPV10-50H01DV 2) (UEF 3)
- Friedrich Heat Pump 40-Gallon (PROH50 T2 FD400-15) (UEF 3.75)
- Lochinvar Heat Pump 50-Gallon (HPV050KD 2) (UEF 3)
- RELIANCE WATER HEATERS Heat Pump 50-Gallon (10-50-DHPTV 2) (UEF 3)
- Rheem Heat Pump 40-Gallon (PROPH50 T2 RH375-15) (UEF 3.75)
Frequently asked questions
Is the American Heat Pump 50-Gallon (HPV10250H009DV 2) ENERGY STAR certified?
Yes, the American Heat Pump 50-Gallon (HPV10250H009DV 2) holds a current ENERGY STAR certification for water heating efficiency (UEF 3).
How much does the American Heat Pump 50-Gallon (HPV10250H009DV 2) cost to run per year?
About $264 per year at national average energy rates, based on its certified annual energy use under the DOE test draw pattern. Your rate and usage change this figure.
What electrical circuit does the American Heat Pump 50-Gallon (HPV10250H009DV 2) need?
The American Heat Pump 50-Gallon (HPV10250H009DV 2) runs on a 120 V circuit drawing up to 15 A — many installations use an existing outlet with no new wiring.
Is the American Heat Pump 50-Gallon (HPV10250H009DV 2) a smart water heater?
Yes, the American Heat Pump 50-Gallon (HPV10250H009DV 2) is connected-capable, with app control and eligibility for most utility demand-response programs.